Breakdown behavior of a 10 mm point-sphere gap is investigated for R12, R12 (Dichlorodifluoromethane, CCL2F2), air mixtures for pressures of up to 60psi. It is shown that at high gas pressures, mixtures containing high R12 content can have breakdown voltages higher than the corresponding values in air. Furthermore, these voltages are compared with the SF6. And make a comparison of R12 and SF6 in different scenarios i.e. GWP, cost, dielectric strength. Then Ac voltage breakdown characteristics of various combinations of insulating filler in transformer oil for use in transformers were investigated, with the aim of reducing the amount of oil and thus the cost. Tests were conducted on a sphere–sphere electrode in a horizontal arrangement and a sphere–plane electrode in a vertical arrangement. The Breakdown characteristics were also investigated in a modal in which Nomex paper was inserted between filler and the high-voltage electrode. Based on the experiments, optimum conditions are proposed for the application of transformer oil to transformers. Detailed results of investigations of both gas and composite insulating oil are described and discussed in this paper.

Résumé des informations

Titre
HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers
Cours
POWER SYSTEM ENGINEERING
Auteurs
Année
2013
Pages
5
N° de catalogue
V229763
ISBN (ebook)
9783656457985
Taille d'un fichier
920 KB
Langue
anglais
Annotations
COMSATS ABBOTTABAD
Mots clés
hvac, breakdown, mixtures, sphere, electrodes, proposed, composite, liquid, reduce, amount, transformer, transformers
Citation du texte
Muhammad Junaid (Auteur)Mehran Tahir (Auteur)Muhammad Aamir (Auteur), 2013, HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers, Munich, GRIN Verlag, https://www.grin.com/document/229763

Commentaires

  • Pas encore de commentaires.
Lire l'ebook
Titre: HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers



Télécharger textes

Votre devoir / mémoire:

- Publication en tant qu'eBook et livre
- Honoraires élevés sur les ventes
- Pour vous complètement gratuit - avec ISBN
- Cela dure que 5 minutes
- Chaque œuvre trouve des lecteurs

Devenir un auteur