HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers


Trabajo de Investigación, 2013

5 Páginas


Resumen o Introducción

Breakdown behavior of a 10 mm point-sphere gap is investigated for R12, R12 (Dichlorodifluoromethane, CCL2F2), air mixtures for pressures of up to 60psi. It is shown that at high gas pressures, mixtures containing high R12 content can have breakdown voltages higher than the corresponding values in air. Furthermore, these voltages are compared with the SF6. And make a comparison of R12 and SF6 in different scenarios i.e. GWP, cost, dielectric strength. Then Ac voltage breakdown characteristics of various combinations of insulating filler in transformer oil for use in transformers were investigated, with the aim of reducing the amount of oil and thus the cost. Tests were conducted on a sphere–sphere electrode in a horizontal arrangement and a sphere–plane electrode in a vertical arrangement. The Breakdown characteristics were also investigated in a modal in which Nomex paper was inserted between filler and the high-voltage electrode. Based on the experiments, optimum conditions are proposed for the application of transformer oil to transformers. Detailed results of investigations of both gas and composite insulating oil are described and discussed in this paper.

Detalles

Título
HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers
Curso
POWER SYSTEM ENGINEERING
Autores
Año
2013
Páginas
5
No. de catálogo
V229763
ISBN (Ebook)
9783656457985
Tamaño de fichero
920 KB
Idioma
Inglés
Notas
COMSATS ABBOTTABAD
Palabras clave
hvac, breakdown, mixtures, sphere, electrodes, proposed, composite, liquid, reduce, amount, transformer, transformers
Citar trabajo
Muhammad Junaid (Autor)Mehran Tahir (Autor)Muhammad Aamir (Autor), 2013, HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers, Múnich, GRIN Verlag, https://www.grin.com/document/229763

Comentarios

  • No hay comentarios todavía.
Leer eBook
Título: HVAC Breakdown of R12, R12 – Air Mixtures in Sphere gap Electrodes and Proposed Composite insulating Liquid to Reduce the Amount of Transformer Oil In Transformers



Cargar textos

Sus trabajos académicos / tesis:

- Publicación como eBook y libro impreso
- Honorarios altos para las ventas
- Totalmente gratuito y con ISBN
- Le llevará solo 5 minutos
- Cada trabajo encuentra lectores

Así es como funciona